Specification: A benchtop unit comprising a vacuum formed ABS plastic plinth with integral electrical console onto which is mounted the stainless steel, packed fixed bed adsorption column, hot water...
- Height 325 mm, diameter 58 mm - Stainless steel jacket for temperature control - Gas distribution plate at entry to column - Bed of glass beads for good gas distribution and maintenance of steady-state temperature - Six thermocouples spaced evenly along the length of the column
The introduces students to the fundamentals of adsorption and desorption processes using a packed bed reactor. The unit is fitted with a stainless steel reactor column in which the adsorbent, activated carbon, is packed.
There are six thermocouples sited along the length of the column, which enable the adsorption/desorption fronts to be followed (Adsorption/desorption of CO2 leads to changes in temperature). A hot water circulation system, also containing a thermocouple (T7), is connected to the jacket of the column to enable accurate temperature control via a PID temperature controller so that the desired processing temperature is accurately maintained.
The system is equipped with all the valves required for flow direction control, flow rate control and pressure relief for safety. Electronic flowmeters monitor the flow rate of both the carrier gas, helium and the absorbate, carbon dioxide. These combined with the column temperature sensors and the IR detector, for measuring CO2 concentration; enable the processes to be followed closely and a wide range of operating variables to be examined.
Operation pressure: 0-0.5 bars Gas flow rates: 0 < 5 SLPM (He), 0 < 1 SLPM (CO2) Column capacity: 480 cm3 Gases: CO2, He Relief valve pressure: 20 psi Column operating temperature: 25 - 45°C
- Height 325 mm, diameter 58 mm - Stainless steel jacket for temperature control - Gas distribution plate at entry to column - Bed of glass beads for good gas distribution and maintenance of steady-state temperature - Six thermocouples spaced evenly along the length of the column
The introduces students to the fundamentals of adsorption and desorption processes using a packed bed reactor. The unit is fitted with a stainless steel reactor column in which the adsorbent, activated carbon, is packed.
There are six thermocouples sited along the length of the column, which enable the adsorption/desorption fronts to be followed (Adsorption/desorption of CO2 leads to changes in temperature). A hot water circulation system, also containing a thermocouple (T7), is connected to the jacket of the column to enable accurate temperature control via a PID temperature controller so that the desired processing temperature is accurately maintained.
The system is equipped with all the valves required for flow direction control, flow rate control and pressure relief for safety. Electronic flowmeters monitor the flow rate of both the carrier gas, helium and the absorbate, carbon dioxide. These combined with the column temperature sensors and the IR detector, for measuring CO2 concentration; enable the processes to be followed closely and a wide range of operating variables to be examined.
Operation pressure: 0-0.5 bars Gas flow rates: 0 < 5 SLPM (He), 0 < 1 SLPM (CO2) Column capacity: 480 cm3 Gases: CO2, He Relief valve pressure: 20 psi Column operating temperature: 25 - 45°C
No Review Yet.
Copyrights © 2019 All Rights Reserved by Atico
Product
Reviews
add Review
reviews
No Review Yet.