Losses Due To Pipe Fittings Sudden Enlargement & Contraction

Categories:

Losses Due To Pipe Fittings Sudden Enlargement & Contraction It comprises of 1/2 bend and elbow. Pressure tapings are provided at inlet and outlet of these fittings under test.  A differential man...


title icon
Product

Description

Losses Due To Pipe Fittings Sudden Enlargement & Contraction

It comprises of 1/2 bend and elbow. Pressure tapings are provided at inlet and outlet of these fittings under test.  A differential manometer fitted in the line gives pressure, loss of individual fittings. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates.
Experiments:
  • To determine loss of head in the fittings at various water flow rates
  • To measure the loss coefficient for the pipe fittings
Utilities Required:
  • Electric supply 0.5 kW, 220V AC, Single Phase
  • Water supply Tap water connection ” BSP Distilled water @ 60 liters (optional)
  • Floor Area with Drain facility
Technical Specifications:
  • Sudden Enlargement: From 15 mm to 25 mm
  • Sudden Contraction: From 25 mm to 15 mm
  • Bend: 1/2 “
  • Elbow: 1/2 “
  • Ball valve: 1/2 “
  • Gate valve: 1/2 “
  • Instruction Manual: An english instruction manual will be provided along with the Apparatus
  • The whole set-up is well designed and arranged in a good quality painted structure


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

Losses Due To Pipe Fittings Sudden Enlargement & Contraction

It comprises of 1/2 bend and elbow. Pressure tapings are provided at inlet and outlet of these fittings under test.  A differential manometer fitted in the line gives pressure, loss of individual fittings. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates.
Experiments:
  • To determine loss of head in the fittings at various water flow rates
  • To measure the loss coefficient for the pipe fittings
Utilities Required:
  • Electric supply 0.5 kW, 220V AC, Single Phase
  • Water supply Tap water connection ” BSP Distilled water @ 60 liters (optional)
  • Floor Area with Drain facility
Technical Specifications:
  • Sudden Enlargement: From 15 mm to 25 mm
  • Sudden Contraction: From 25 mm to 15 mm
  • Bend: 1/2 “
  • Elbow: 1/2 “
  • Ball valve: 1/2 “
  • Gate valve: 1/2 “
  • Instruction Manual: An english instruction manual will be provided along with the Apparatus
  • The whole set-up is well designed and arranged in a good quality painted structure

title icon
Product

Reviews

add Review
reviews

    No Review Yet.