quick overview :
PLC Trainer
Technical Specifications of PLC Trainer :
Control Method : Cyclic execution of stored program, Time-driven operation,
Interrupt task operation
I/O Control Method : Scan synchronized batch processing method (Refresh Method)
Program Language : LD (Ladder Diagram), IL (Instruction list), SFC (Sequential Function chart)
Number of Instructions : LD(20 EA), IL (13 EA), SFC (194 EA)
Processing speed : 0.2/Step
Program Memory Capacity : 128 Kbyte
Maximum I/O Points : 512 points (With 16 pt modules), 1024 points (With 32 pt modules)
2048 points (With 64 pt modules)
Digital Input :
Input Point : 16 Points ( 2 EA )
Rated input Voltage : DC 12/24 V
Common Method : 8 Points / 1 Com
Insulated Method : Photo Coupler Insulation
Digital Output :
Output Point : 16 Points ( 2 EA )
Rated Load Voltage : DC 12V, AC 220V
Rated Load Current : Max. 2A
Common Method : 8 Points / 1 Com
Insulation method : Relay Insulation
Power Module : AC 50Hz / 60Hz, ; DC 5V/4A, 24V/0.7A
Vibration Proof Module : Vibration proof for non use slot
Base : 8 slot ( maximum number of module attach 8 EA )
Trainer Power Supply :
Power : AC, 50Hz / 60Hz
Meter : 1 EA
Main power ( Built in current protection device ) : 1 unit
PLC power ( built in Current protection device ) : 1 unit
DC output power (DC 24V) : 1 Unit
Output Terminal : 4 EA
Sensor Input and Motor Device :
DC Motor (DC 24V) : 1 Unit
Coupling : circular type ( Hole 4 EA / Magnetic 1 EA )
Photo sensor ( Detection Distance : 200 mm ) : 1 EA
Proximity Sensor ( Detection Distance : 8 mm ) : 1 EA
Power for sensor : DC 12V ~ 24V
Input Signal Device :
Non lock type push button : 7 EA
Lock type push button : 1 EA
Digital switch (BCD, 2 digits) : 1 Unit
Output Signal Indication :
Output Lamp (DC 24V) : 7 EA
Buzzer (DC 24V) : 1 EA
Digital switch (BCD, 2 digits) : 1 Unit
Digital I/O Terminals :
Input : 32 Points ( 16 points / 1 COM Total 4 EA )
Output : 32 Points ( 16 Points / 1 COM Total 4 EA )
Training Contents :
Basic Commands, LOAD and LOAD NOT
Basic Commands, AND and AND NOT
Basic Commands, OR and OR NOT
Basic Command, Coil
Commands, SET and RST
Self holding circuit
Transition – Sensing Coils
Function Block Command, TON
Function Block Command, TOF
Function Commands, CTU & CTD
Function Commands, MCS and MCS CLR
Quiz Circuit
Electric Motor and Pulse sensor 1
Electric Motor and Pulse sensor 2
Product
Reviews
add Review
reviews
No Review Yet.