The 32-Way Pressure Display Unit is an optional ancillary to modular Subsonic Wind Tunnels it is included with. It measures and displays up to 32 pressures from models, Pitot-static tubes and other measuring instruments fitted to a wind tunnel. It is ideally suited to applications where multiple pressure measurements are required, for example in boundary layer and tapped aerofoil model investigations. The unit mounts onto the control and instrumentation frame of the wind tunnel. Connection to each of the 32 calibrated pressure transducers is via quick-release pressure inputs mounted on the front panel of the unit. This allows easy and quick connection between the unit and an experiment mounted in the wind tunnel. All pressures are measured with respect to atmosphere. The unit has an integral liquid crystal display with a scroll switch that allows all 32 channels to be viewed in groups of four at any time. The conditioned outputs of the pressure sensors, and any other connected compatible electronic instruments, may be output to Versatile Data Acquisition System (VDAS®, available separately) to allow computer based data acquisition and display. Using VDAS® enables accurate real-time data capture, monitoring, display, calculation and charting of all relevant parameters on a suitable computer (computer not included). When the 32- Way Pressure Display Unit is used with the system it allows laboratory time to be used more efficiently because data can be captured and processed much more quickly than when using manual techniques. The facility in the software to average data to remove the fluctuations inherent in wind tunnel measurements, enhances the quality of the results by making their interpretation much easier. This option provides significant experimental advantages over conventional instruments such as manometers.

Features
Included with modular Subsonic Wind Tunnel
Ancillary to other modular Subsonic Wind Tunnels 
Measures and displays up to 32 pressures from models, Pitot static tubes and other devices
Quicker, easier and more versatile than using liquid manometers
Integral LCD allows direct pressure measurement
Measures pressures with respect to atmosphere
Fully compatible with Versatile Data Acquisition System (VDAS®) to enable accurate real-time data capture, monitoring and display on a computer 

Specifications
ATICO is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specifi cation without prior notice.
Dimensions:
Nett: height 450 mm x width 350 mm x depth 220 mm
Packed: 0.11 m3
Weight:
Nett: 10 kg
Packed: 20 kg
Pressure sensors:
32 pressure transducers calibrated at a maximum of ± 7 kPa 

Operating Conditions
Operating Enviroment:
Well ventilated laboratory
Storage Temprature Range :
–25°C to +55°C (when packed for transport)
Operating Temprature range:
+5°C to +40°C
Operating relative humidity range:
80% at temperatures < 31°C decreasing linearly to 50% at 40°C


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

Description
The 32-Way Pressure Display Unit is an optional ancillary to modular Subsonic Wind Tunnels it is included with. It measures and displays up to 32 pressures from models, Pitot-static tubes and other measuring instruments fitted to a wind tunnel. It is ideally suited to applications where multiple pressure measurements are required, for example in boundary layer and tapped aerofoil model investigations. The unit mounts onto the control and instrumentation frame of the wind tunnel. Connection to each of the 32 calibrated pressure transducers is via quick-release pressure inputs mounted on the front panel of the unit. This allows easy and quick connection between the unit and an experiment mounted in the wind tunnel. All pressures are measured with respect to atmosphere. The unit has an integral liquid crystal display with a scroll switch that allows all 32 channels to be viewed in groups of four at any time. The conditioned outputs of the pressure sensors, and any other connected compatible electronic instruments, may be output to Versatile Data Acquisition System (VDAS®, available separately) to allow computer based data acquisition and display. Using VDAS® enables accurate real-time data capture, monitoring, display, calculation and charting of all relevant parameters on a suitable computer (computer not included). When the 32- Way Pressure Display Unit is used with the system it allows laboratory time to be used more efficiently because data can be captured and processed much more quickly than when using manual techniques. The facility in the software to average data to remove the fluctuations inherent in wind tunnel measurements, enhances the quality of the results by making their interpretation much easier. This option provides significant experimental advantages over conventional instruments such as manometers.

Features
Included with modular Subsonic Wind Tunnel
Ancillary to other modular Subsonic Wind Tunnels 
Measures and displays up to 32 pressures from models, Pitot static tubes and other devices
Quicker, easier and more versatile than using liquid manometers
Integral LCD allows direct pressure measurement
Measures pressures with respect to atmosphere
Fully compatible with Versatile Data Acquisition System (VDAS®) to enable accurate real-time data capture, monitoring and display on a computer 

Specifications
ATICO is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specifi cation without prior notice.
Dimensions:
Nett: height 450 mm x width 350 mm x depth 220 mm
Packed: 0.11 m3
Weight:
Nett: 10 kg
Packed: 20 kg
Pressure sensors:
32 pressure transducers calibrated at a maximum of ± 7 kPa 

Operating Conditions
Operating Enviroment:
Well ventilated laboratory
Storage Temprature Range :
–25°C to +55°C (when packed for transport)
Operating Temprature range:
+5°C to +40°C
Operating relative humidity range:
80% at temperatures < 31°C decreasing linearly to 50% at 40°C