Aerofoil With Tappings

Categories: Engineering Lab Equipment

DescriptionThis module consists of a duct with transparent front and rear, between which is mounted a symmetrical aerofoil with a NACA profile. The aerofoil has 12 tapping points at various chordwise...


title icon
Product

Description

Description
This module consists of a duct with transparent front and rear, between which is mounted a symmetrical aerofoil with a NACA profile. The aerofoil has 12 tapping points at various chordwise positions on its surface allowing the pressure to be measured at that point. The tapping points are permanently connected to a manifold mounted on the duct showing the tapping position and number for easy reference. The experiment mounts on the Air Flow Bench contraction using toggle clamps. Each one of the tappings connects to the manometer (ancillary) via flexible tubes fitted with quick-release couplings. The aerofoil may be accurately rotated to various angles of incidence (attack) to the air using the control and printed scale on the front of the duct.

Learning Outcomes
The visualisation and measurement of the pressure distribution around an aerofoil section.
Lift characteristics and stall angle of an aerofoil.

Specifications
ATICO is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specifi cation without prior notice.
Packed dimensions and weight: 0.2 m3; 10 kg

Operating Conditions
Operating Enviroment:
Laboratory
Storage Temprature Range :
–25°C to +55°C (when packed for transport)
Operating Temprature range:
+5°C to +40°C
Operating relative humidity range:
80% at temperatures < 31°C decreasing linearly to 50% at 40°C


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

Description
This module consists of a duct with transparent front and rear, between which is mounted a symmetrical aerofoil with a NACA profile. The aerofoil has 12 tapping points at various chordwise positions on its surface allowing the pressure to be measured at that point. The tapping points are permanently connected to a manifold mounted on the duct showing the tapping position and number for easy reference. The experiment mounts on the Air Flow Bench contraction using toggle clamps. Each one of the tappings connects to the manometer (ancillary) via flexible tubes fitted with quick-release couplings. The aerofoil may be accurately rotated to various angles of incidence (attack) to the air using the control and printed scale on the front of the duct.

Learning Outcomes
The visualisation and measurement of the pressure distribution around an aerofoil section.
Lift characteristics and stall angle of an aerofoil.

Specifications
ATICO is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specifi cation without prior notice.
Packed dimensions and weight: 0.2 m3; 10 kg

Operating Conditions
Operating Enviroment:
Laboratory
Storage Temprature Range :
–25°C to +55°C (when packed for transport)
Operating Temprature range:
+5°C to +40°C
Operating relative humidity range:
80% at temperatures < 31°C decreasing linearly to 50% at 40°C