Control Unit For Ventilation System

Categories: Engineering Lab Equipment

The trainer is required if the ventilation system is to be used for experiments with room temperature control.The trainer is connected between the ventilation system and an external source of hot wate...


title icon
Product

Description

The trainer is required if the ventilation system is to be used for experiments with room temperature control.
The trainer is connected between the ventilation system and an external source of hot water using quick-release couplings. With this arrangement it is possible to demonstrate room temperature control in ventilation systems.
Only original parts were used for the trainer.

Learning Objectives/Experiments
Temperature control of the air flow in a ventilation system

Features
Temperature control for ventilation system

Specification
Temperature control of a ventilation system
Circulating pump
3-way mixing valve DN 20
Electronic controller with temperature sensor and setting of the reference variable
3 thermometers and 1 temperature sensor with display
Quick-release couplings for connection to hot water supply and ventilation system

Technical data
Pump
power consumption: 70W
max. flow rate: 60L/min
max. head: 4m
Measuring ranges
temperature:
1x -50…600°C
3x 0…120°C
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase
120V, 60Hz, 1 phase
UL/CSA optional
LxWxH: 1000x650x1450mm
Weight: approx. 65kg


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

The trainer is required if the ventilation system is to be used for experiments with room temperature control.
The trainer is connected between the ventilation system and an external source of hot water using quick-release couplings. With this arrangement it is possible to demonstrate room temperature control in ventilation systems.
Only original parts were used for the trainer.

Learning Objectives/Experiments
Temperature control of the air flow in a ventilation system

Features
Temperature control for ventilation system

Specification
Temperature control of a ventilation system
Circulating pump
3-way mixing valve DN 20
Electronic controller with temperature sensor and setting of the reference variable
3 thermometers and 1 temperature sensor with display
Quick-release couplings for connection to hot water supply and ventilation system

Technical data
Pump
power consumption: 70W
max. flow rate: 60L/min
max. head: 4m
Measuring ranges
temperature:
1x -50…600°C
3x 0…120°C
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase
120V, 60Hz, 1 phase
UL/CSA optional
LxWxH: 1000x650x1450mm
Weight: approx. 65kg