HSI Training System Refrigeration And Air Conditioning Technology, Base Unit

Categories: Engineering Lab Equipment

The base unit is, dependent on the objective of the experiment, extended into complete refrigeration circuit with one of the models available as accessories (refrigerator, refrigeration system with...


title icon
Product

Description

The base unit is, dependent on the objective of the experiment, extended into complete refrigeration circuit with one of the models available as accessories (refrigerator, refrigeration system with refrigeration and freezing stage, simple air conditioning system, air conditioning). The main components of it are compressor, condenser and receiver plus electrical and communications systems. The models are plugged onto the base unit and connected hydraulically with refrigerant hoses and electrically with cables. Self-sealing couplings reduce the refrigerant loss to a minimum. All components are arranged well visible to allow their operation to be monitored. The modern and powerful software is an integral part of the training system in the form of hardware/software integration (HSI). It enables the comfortable execution and analysis of the experiments. The experimental unit is connected to the PC via a USB interface.

 

Learning Objectives/Experiments

In conjunction with

Fundamentals of the refrigeration cycle

Fundamentals of air conditioning

Components in a refrigeration system/air conditioning system

System operation

Fault finding

 

Features

Base unit for the setup of basic experiments in refrigeration and air conditioning technology

Modern learning environment through hardware/software integration (HSI)

Four models on refrigeration and air conditioning technology

Specification

Basic experiments on the operation of refrigeration and air conditioning systems by combining the base unit and models

Training system with HSI technology

Condensing unit consisting of compressor, condenser and receiver

Connection between condensing unit and model via refrigerant hoses

Model attached securely on It with fasteners

Manometer for refrigerant with temperature scale

Refrigerant R513A, GWP: 631

System control via solenoid valves and software

Functions of the software: educational software, data acquisition, system operation

 

Technical Data

Compressor

refrigeration capacity: 463W at 7,2/54,4°C

power consumption: 288W at 7,2/54,4°C

Receiver: 0,7L

Refrigerant

R513A

GWP: 631

filling volume: 700g

CO2-equivalent: 0,4t

Measuring ranges

temperature: 1x -50…50°C, 3x 0…100°C

pressure:

1x intake side: -1…9bar

2x delivery side: -1…15bar

230V, 50Hz, 1 phase

230V, 60Hz, 1 phase

120V, 60Hz, 1 phase

 


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

The base unit is, dependent on the objective of the experiment, extended into complete refrigeration circuit with one of the models available as accessories (refrigerator, refrigeration system with refrigeration and freezing stage, simple air conditioning system, air conditioning). The main components of it are compressor, condenser and receiver plus electrical and communications systems. The models are plugged onto the base unit and connected hydraulically with refrigerant hoses and electrically with cables. Self-sealing couplings reduce the refrigerant loss to a minimum. All components are arranged well visible to allow their operation to be monitored. The modern and powerful software is an integral part of the training system in the form of hardware/software integration (HSI). It enables the comfortable execution and analysis of the experiments. The experimental unit is connected to the PC via a USB interface.

 

Learning Objectives/Experiments

In conjunction with

Fundamentals of the refrigeration cycle

Fundamentals of air conditioning

Components in a refrigeration system/air conditioning system

System operation

Fault finding

 

Features

Base unit for the setup of basic experiments in refrigeration and air conditioning technology

Modern learning environment through hardware/software integration (HSI)

Four models on refrigeration and air conditioning technology

Specification

Basic experiments on the operation of refrigeration and air conditioning systems by combining the base unit and models

Training system with HSI technology

Condensing unit consisting of compressor, condenser and receiver

Connection between condensing unit and model via refrigerant hoses

Model attached securely on It with fasteners

Manometer for refrigerant with temperature scale

Refrigerant R513A, GWP: 631

System control via solenoid valves and software

Functions of the software: educational software, data acquisition, system operation

 

Technical Data

Compressor

refrigeration capacity: 463W at 7,2/54,4°C

power consumption: 288W at 7,2/54,4°C

Receiver: 0,7L

Refrigerant

R513A

GWP: 631

filling volume: 700g

CO2-equivalent: 0,4t

Measuring ranges

temperature: 1x -50…50°C, 3x 0…100°C

pressure:

1x intake side: -1…9bar

2x delivery side: -1…15bar

230V, 50Hz, 1 phase

230V, 60Hz, 1 phase

120V, 60Hz, 1 phase

 

title icon
Product

Reviews

add Review
reviews

    No Review Yet.