quick overview :
An open pipe system that simulates a domestic installation for drinking water with four different levels is mounted on the panel of the trainer. The levels represent the cellar (drinking water connection level) and three floors. It is possible to simulate a pipe fracture or a pressure drop. During this process the return of contaminated water into the drinking water pipe can be observed.
Learning Objectives/Experiments
Function of various safety devices
Pipe separator
Backflow preventer
Pipe vents
Prevention of the return of contaminated water back into the drinking water pipe
Features
Safety and hygiene of drinking water pipes
Drinking water installation for a three-floor house with cellar
Investigations on the return of contaminated water back into the drinking water pipe
Specification
Simulation of 3 floors and a cellar of a house
Devices to prevent the return of contaminated water into the drinking water pipe
Possible simulations: pipe fracture, pressure drop
Pipe system made of transparent material
2 risers with vent
6 outlet valves with hose connections
3 transparent water tanks
Pipe separator, backflow preventer and riser vent as safety devices
Water meter in feed pipe
Technical data
2 backflow preventers: DN 20
1 pipe separator: DN 20
2 riser vents: DN 20
1 flow rate pipe vent with backflow preventer: DN 20
1 flow rate pipe vent without backflow preventer: DN 20
2 sealing plugs: DN 20
2 pipe sections: DN 20
3 Plexiglass tanks: 6,5L
Dimensions and weight
lxwxh: 1650x200x1100mm (panel)
Weight: approx. 45kg (panel)
Product