Split System Air Conditioner

Categories: Engineering Lab Equipment

Split system air conditioners are used to cool, dehumidify and also heat rooms. The consist of an inner and outer unit.In the inner unit there is a heat exchanger with fan working as an evaporator in...


title icon
Product

Description

Split system air conditioners are used to cool, dehumidify and also heat rooms. The consist of an inner and outer unit.
In the inner unit there is a heat exchanger with fan working as an evaporator in the refrigeration circuit during cooling operation. During heating operation it works as a condenser. The outer unit contains a compressor, another heat exchanger, expansion element (e.g. capillary tube) and an element enabling the change-over from cooling to heating operation. In cooling operation the evaporating refrigerant in the heat exchanger of the inner unit withdraws heat from the room air. In the outer unit the heat in the heat exchanger is discharged to the ambient air by condensing the refrigerant. During heating operation the heat transport is reversed.

Learning Objectives/Experiments
Design and operation of a split system air conditioner
6 operating modes
Cooling
Dehumidifying (slight cooling)
Heating
Ventilation (only the fan of the inner unit)
Automatic (operating mode suitable for the room temperature)
Test of cooling function
3 additional functions
“Sleep” (switch-off after several hours)
“Swing” (air outlet lamella position)
Timer for switching on and off
Remote control functions

Specification
Trainer from the practical series for the training of mechatronics engineers for refrigeration
Design and operation of a commercial split system air conditioner
iIllustration of the split principle using a dividing wall
6 different operating modes: heating, cooling, dehumidifying, ventilation, automatic, test
3 additional functions configurable via remote control: sleep, swing, timer
2 refrigerant manometers indicate the low and high pressure of the compressor
Battery operated remote control

Technical Data
Split system air conditioner
power consumption: approx. 1,2kW at 24/35°C
cooling capacity: approx. 3,5kW at 24/35°C
max. volumetric air flow rate (inner unit): approx. 420m3/h
dehumidification (inner unit): approx. 0,8L/h
timer: 24h
Refrigerant
R32
GWP: 675
filling volume: 700g
CO2-equivalent: 0,5t
Measuring ranges
pressure: 2x -1…40bar
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

Split system air conditioners are used to cool, dehumidify and also heat rooms. The consist of an inner and outer unit.
In the inner unit there is a heat exchanger with fan working as an evaporator in the refrigeration circuit during cooling operation. During heating operation it works as a condenser. The outer unit contains a compressor, another heat exchanger, expansion element (e.g. capillary tube) and an element enabling the change-over from cooling to heating operation. In cooling operation the evaporating refrigerant in the heat exchanger of the inner unit withdraws heat from the room air. In the outer unit the heat in the heat exchanger is discharged to the ambient air by condensing the refrigerant. During heating operation the heat transport is reversed.

Learning Objectives/Experiments
Design and operation of a split system air conditioner
6 operating modes
Cooling
Dehumidifying (slight cooling)
Heating
Ventilation (only the fan of the inner unit)
Automatic (operating mode suitable for the room temperature)
Test of cooling function
3 additional functions
“Sleep” (switch-off after several hours)
“Swing” (air outlet lamella position)
Timer for switching on and off
Remote control functions

Specification
Trainer from the practical series for the training of mechatronics engineers for refrigeration
Design and operation of a commercial split system air conditioner
iIllustration of the split principle using a dividing wall
6 different operating modes: heating, cooling, dehumidifying, ventilation, automatic, test
3 additional functions configurable via remote control: sleep, swing, timer
2 refrigerant manometers indicate the low and high pressure of the compressor
Battery operated remote control

Technical Data
Split system air conditioner
power consumption: approx. 1,2kW at 24/35°C
cooling capacity: approx. 3,5kW at 24/35°C
max. volumetric air flow rate (inner unit): approx. 420m3/h
dehumidification (inner unit): approx. 0,8L/h
timer: 24h
Refrigerant
R32
GWP: 675
filling volume: 700g
CO2-equivalent: 0,5t
Measuring ranges
pressure: 2x -1…40bar
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase