Subsonic Wind Tunnel 305mm

Categories: Engineering Lab Equipment

DescriptionAir enters the tunnel through an aerodynamically designedeffuser (cone) that accelerates the air linearly. It then enters the working section and passes through a grille before moving throu...


title icon
Product

Description

Description
Air enters the tunnel through an aerodynamically designedeffuser (cone) that accelerates the air linearly. It then enters the working section and passes through a grille before moving through a diffuser and then to a variable-speed axial fan. The grille protects the fan from damage by loose objects. The air leaves the fan, passes through a silencer unit and then back out to the atmosphere. A separate control and instrumentation unit controls the speed of the axial fan (and the air velocity in the working section). The control and instrumentation unit also includes manometers and electrical outlets to supply electrical power to other optional instruments. A metal frame supports the wind tunnel. The frame includes lockable castors for convenient mobility. Working Section The working section of the tunnel is a square section with a clear roof, sides and floor. The sides are removable. The floor and each side panel has a special position to support the optional wind tunnel models. Supplied with the wind tunnel are a protractor and a model holder to support and accurately adjust the angle of any models fitted. Two traversing probes fit on the working section. One is a Pitot-static tube and the other a standard Pitot tube. They fit upstream and downstream of any models and connect to the manometers on the instrumentation unit (or other optional instruments) to show pressure.

Features
A wind tunnel for conducting experiments in aerodynamics
Safe, compact, open-circuit suction wind tunnel – a cost effective solution when compared to full-sale wind tunnels
The optional ancillaries work with Versatile Data Acquisition System 
Additional models and instruments available to extend the range of experiments
Wind tunnel controls mount on a separate, free-standing instrument frame for ease of use
The wind tunnel has wheels for easy mobility
Also available as a starter set with a basic lift and drag balance and a set of models

Specifications
ATICO is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specification without prior notice.
Nett dimensions and weight (assembled):
3700 mm x 1065 mm x height 1900 mm and 293 kg
A p p r o x i m at e pa c k e d v o l u m e a n d w e i g h t: 4.9 m3 and 450 kg
Space needed: Solid, level floor – allow at least 2 m of free space around the inlet and 4 m at the outlet
Working section: 305 mm x 305 mm, and 600 mm long.
Air velocity: 0 to 36 m.s–1
Noise levels: 80 dB(A) at operators ear level.
Electrical supply (three phase): 200 VAC to 240 VAC 50 Hz/60 Hz (20 A) or, 380 VAC to 440 VAC 50 Hz/60 Hz (16 A)
Operating Conditions
Operating environment:
Laboratory
S t o r a g e t e m p e r at u r e r a n g e : –25°C to +55°C (when packed for transport)
Operating temperature range: +5°C to +40°C
O p e r at i n g r e l at i v e h u m i d i t y r a n g e :
80% at temperatures < 31°C decreasing linearly to 50% at 40°C


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

Description
Air enters the tunnel through an aerodynamically designedeffuser (cone) that accelerates the air linearly. It then enters the working section and passes through a grille before moving through a diffuser and then to a variable-speed axial fan. The grille protects the fan from damage by loose objects. The air leaves the fan, passes through a silencer unit and then back out to the atmosphere. A separate control and instrumentation unit controls the speed of the axial fan (and the air velocity in the working section). The control and instrumentation unit also includes manometers and electrical outlets to supply electrical power to other optional instruments. A metal frame supports the wind tunnel. The frame includes lockable castors for convenient mobility. Working Section The working section of the tunnel is a square section with a clear roof, sides and floor. The sides are removable. The floor and each side panel has a special position to support the optional wind tunnel models. Supplied with the wind tunnel are a protractor and a model holder to support and accurately adjust the angle of any models fitted. Two traversing probes fit on the working section. One is a Pitot-static tube and the other a standard Pitot tube. They fit upstream and downstream of any models and connect to the manometers on the instrumentation unit (or other optional instruments) to show pressure.

Features
A wind tunnel for conducting experiments in aerodynamics
Safe, compact, open-circuit suction wind tunnel – a cost effective solution when compared to full-sale wind tunnels
The optional ancillaries work with Versatile Data Acquisition System 
Additional models and instruments available to extend the range of experiments
Wind tunnel controls mount on a separate, free-standing instrument frame for ease of use
The wind tunnel has wheels for easy mobility
Also available as a starter set with a basic lift and drag balance and a set of models

Specifications
ATICO is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specification without prior notice.
Nett dimensions and weight (assembled):
3700 mm x 1065 mm x height 1900 mm and 293 kg
A p p r o x i m at e pa c k e d v o l u m e a n d w e i g h t: 4.9 m3 and 450 kg
Space needed: Solid, level floor – allow at least 2 m of free space around the inlet and 4 m at the outlet
Working section: 305 mm x 305 mm, and 600 mm long.
Air velocity: 0 to 36 m.s–1
Noise levels: 80 dB(A) at operators ear level.
Electrical supply (three phase): 200 VAC to 240 VAC 50 Hz/60 Hz (20 A) or, 380 VAC to 440 VAC 50 Hz/60 Hz (16 A)
Operating Conditions
Operating environment:
Laboratory
S t o r a g e t e m p e r at u r e r a n g e : –25°C to +55°C (when packed for transport)
Operating temperature range: +5°C to +40°C
O p e r at i n g r e l at i v e h u m i d i t y r a n g e :
80% at temperatures < 31°C decreasing linearly to 50% at 40°C