Three-Way Mixing Valve Training Panel

Categories: Engineering Lab Equipment

The trainer was designed for heating and plumbing trainees. A three-way mixing valve in a heating system controls the circulation and feed flow temperature of the water flowing in the heating sys...


title icon
Product

Description

The trainer was designed for heating and plumbing trainees.

A three-way mixing valve in a heating system controls the circulation and feed flow temperature of the water flowing in the heating system. A pump circulates the water in the pipe system. The differential pressure across the pipe system is limited using a relief valve. Bimetallic thermometers indicate the temperatures at all relevant points in the heating circuit.

 

Learning Objectives/Experiments

Function and operating behaviour of a three-way mixing valve

Effect of mixing ratio on feed flow or circulating flow temperature

Effect of mixer setting on the flow rate

In conjunction with other training panels in the series, it is possible to set up a complete heating system.

Specification

Trainer on heating systems and plumbing

3-way mixing valve DN 20

Circulating pump

4 rotameters

4 bimetallic thermometers

2 heating water connections DN 15

2 water connections for boiler DN 15

1 differential pressure overflow valve

Water connections made using quick-release couplings

 

Technical Data

Pump

power consumption: 70W

max. flow rate: 60L/min

max. head: 4m

Three-way mixing valve

setting angle: 90°

opening time: 100s

Measuring ranges

flow rate:

3x 150…1700L/h

1x 40…400L/h

temperature: 0…100°C

230V, 50Hz, 1 phase

230V, 60Hz, 1 phase

 


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

The trainer was designed for heating and plumbing trainees.

A three-way mixing valve in a heating system controls the circulation and feed flow temperature of the water flowing in the heating system. A pump circulates the water in the pipe system. The differential pressure across the pipe system is limited using a relief valve. Bimetallic thermometers indicate the temperatures at all relevant points in the heating circuit.

 

Learning Objectives/Experiments

Function and operating behaviour of a three-way mixing valve

Effect of mixing ratio on feed flow or circulating flow temperature

Effect of mixer setting on the flow rate

In conjunction with other training panels in the series, it is possible to set up a complete heating system.

Specification

Trainer on heating systems and plumbing

3-way mixing valve DN 20

Circulating pump

4 rotameters

4 bimetallic thermometers

2 heating water connections DN 15

2 water connections for boiler DN 15

1 differential pressure overflow valve

Water connections made using quick-release couplings

 

Technical Data

Pump

power consumption: 70W

max. flow rate: 60L/min

max. head: 4m

Three-way mixing valve

setting angle: 90°

opening time: 100s

Measuring ranges

flow rate:

3x 150…1700L/h

1x 40…400L/h

temperature: 0…100°C

230V, 50Hz, 1 phase

230V, 60Hz, 1 phase

 

title icon
Product

Reviews

add Review
reviews

    No Review Yet.