DescriptionThe Transmission Line Simulator investigates single-phase and three-phase transmission lines. The configurable simulated transmission lines allow realistic studies of short, medium and long...
Specifications
ATICO
is committed to a programme of continuous improvement; hence we reserve the
right to alter the design and product specification without prior notice.
Nett
dimensions and weight:
1850
mm long x 1870 mm high x 960 mm front to back and 750 kg
Approximate
packed volume and weight: 5 m3 and 950 kg
Line
simulation :
Inductors,
with three-phase line represented in per-unit values
Three
- phase lines :
Five
sections, each at 0.15 p.u. value: 75 km of 132 kV line on a 100 MVA base
One
section at 0.25 p.u. value: 125 km of 132 kV line on a 100 MVA base
Three
- phase load banks :
Resistive,
inductive and capacitive
Other
controls and instrumentation:
Phase
angle meter for single-phase and three-phase
Fault
switch
Single-phase
and three-phase selectable capacitor banks for p and T networks
Switchable
neutral from transformer secondary
Protection
relay:
Overcurrent
relay
Operating
Conditions
Operating
Enviroment:
Laboratory
Storage
Temprature Range :
–25°C
to +55°C (when packed for transport)
Operating
Temprature range:
+5°C
to +40°C
Operating
relative humidity range:
80%
at temperatures < 31°C decreasing linearly to 50% at 40°C
Specifications
ATICO
is committed to a programme of continuous improvement; hence we reserve the
right to alter the design and product specification without prior notice.
Nett
dimensions and weight:
1850
mm long x 1870 mm high x 960 mm front to back and 750 kg
Approximate
packed volume and weight: 5 m3 and 950 kg
Line
simulation :
Inductors,
with three-phase line represented in per-unit values
Three
- phase lines :
Five
sections, each at 0.15 p.u. value: 75 km of 132 kV line on a 100 MVA base
One
section at 0.25 p.u. value: 125 km of 132 kV line on a 100 MVA base
Three
- phase load banks :
Resistive,
inductive and capacitive
Other
controls and instrumentation:
Phase
angle meter for single-phase and three-phase
Fault
switch
Single-phase
and three-phase selectable capacitor banks for p and T networks
Switchable
neutral from transformer secondary
Protection
relay:
Overcurrent
relay
Operating
Conditions
Operating
Enviroment:
Laboratory
Storage
Temprature Range :
–25°C
to +55°C (when packed for transport)
Operating
Temprature range:
+5°C
to +40°C
Operating
relative humidity range:
80%
at temperatures < 31°C decreasing linearly to 50% at 40°C