Automatic Dropping Point Apparatus of Lubricating Grease Over Wide Temperature Range

Categories: Petroleum Testing Equipment
·    The dropping point of a grease is the temperature at which it passes from a semi-solid to a liquid state. The dropping point test determines the cohesiveness of...

-->

Use: ·    The dropping point of a grease is the temperature at which it passes from a semi-solid to a liquid state. The dropping point test determines the cohesiveness of the...


title icon
Product

Description

Use:

·    The dropping point of a grease is the temperature at which it passes from a semi-solid to a liquid state. The dropping point test determines the cohesiveness of the oil and thickener of a grease, or when the thickener breaks down. Dropping point tests are used for quality control to verify that the soap structure has been formed correctly and will withstand high temperatures.

·      Does not apply for PFPE/PTFE thickened greases

Compliance with following International Standards:

·       Dropping Point is also known as ASTM Method Automatic Dropping Point Apparatus.

·       Automatic Dropping Point Apparatus Standard Test Method for Dropping Point of Lubricating Grease Over Wide Temperature Range.

·      The equipment is used for higher temperature grease testing than the ASTM D566 method. The different heating procedure is used as compared with ASTM D566.

Feature:

·       7-inch LCD touch screen HMI with beautiful outlook design. Full English operating system is stalled. Instruction interfaces are clearly displayed to provide guide for test completion.

·       High-performance microprocessor as core of MCU, fully automatic control throughout the whole test procedures.

·       Highly integrated bench top instrument with multiple functions.

·       Specially designed photoelectric sensor for dropping point detection with high sensitivity and fast response.

·       It features double sample holes, single test or dual tests can be performed.

·       Fast temperature rising rate with  ±1℃ metal bath temperature accuracy.

·       It features fault self-diagnosis system and reminder functions.

·       Automatic test results and experiments number saving functions with auto test results printing.

·       User-friendly and easy-to-operate,  average test time is less than 2 minutes.

Specifications:

·       Operating voltage: AC220V, 50Hz

·       Operating power: 1200W

·       Metal bath type: Aluminum

·       Sample channels: 2 holes

·       Temperature sensor: Class A PT100*2

·       Test method: auto photoelectric sensor

·       Temperature control range: R.T. ~ 400℃

·       Temperature control point: 121℃, 232℃, 288℃, 316℃, 343℃

·       Temperature control accuracy: ±1℃

·       Test result capacity: automatic saving 256 test results

·       Printing method: auto thermal printer

 

 

 


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

Use:

·    The dropping point of a grease is the temperature at which it passes from a semi-solid to a liquid state. The dropping point test determines the cohesiveness of the oil and thickener of a grease, or when the thickener breaks down. Dropping point tests are used for quality control to verify that the soap structure has been formed correctly and will withstand high temperatures.

·      Does not apply for PFPE/PTFE thickened greases

Compliance with following International Standards:

·       Dropping Point is also known as ASTM Method Automatic Dropping Point Apparatus.

·       Automatic Dropping Point Apparatus Standard Test Method for Dropping Point of Lubricating Grease Over Wide Temperature Range.

·      The equipment is used for higher temperature grease testing than the ASTM D566 method. The different heating procedure is used as compared with ASTM D566.

Feature:

·       7-inch LCD touch screen HMI with beautiful outlook design. Full English operating system is stalled. Instruction interfaces are clearly displayed to provide guide for test completion.

·       High-performance microprocessor as core of MCU, fully automatic control throughout the whole test procedures.

·       Highly integrated bench top instrument with multiple functions.

·       Specially designed photoelectric sensor for dropping point detection with high sensitivity and fast response.

·       It features double sample holes, single test or dual tests can be performed.

·       Fast temperature rising rate with  ±1℃ metal bath temperature accuracy.

·       It features fault self-diagnosis system and reminder functions.

·       Automatic test results and experiments number saving functions with auto test results printing.

·       User-friendly and easy-to-operate,  average test time is less than 2 minutes.

Specifications:

·       Operating voltage: AC220V, 50Hz

·       Operating power: 1200W

·       Metal bath type: Aluminum

·       Sample channels: 2 holes

·       Temperature sensor: Class A PT100*2

·       Test method: auto photoelectric sensor

·       Temperature control range: R.T. ~ 400℃

·       Temperature control point: 121℃, 232℃, 288℃, 316℃, 343℃

·       Temperature control accuracy: ±1℃

·       Test result capacity: automatic saving 256 test results

·       Printing method: auto thermal printer

 

 

 

title icon
Product

Reviews

add Review
reviews

    No Review Yet.