Technical Features:· Full automatic control, one key start detection, the test process includes measurement, cleaning, drying, test results calculatio...
Technical Features:
·
Full automatic control, one key start detection,
the test process includes measurement, cleaning, drying, test results calculation and data storage. It will
stop automatically after the test.
·
The measuring speed is fast, the fastest measuring time is no more than 30s,
and the average measuring time is less
than 3 minutes.
·
The instrument has dual solvent automatic cleaning function, which can
quickly clean the folded tube viscometer,
and the consumption of cleaning agent in one cleaning process is not
more than 15ml.
·
The instrument adopts high-precision sensors, and the temperature
of the bathtub is uniform and stable,
with a temperature control accuracy of 0.01 ℃.
·
It is convenient and quick to replace the folded
tube viscometer. The viscometer can be replaced without draining the bath liquid. The replacement can
be completed within 2 minutes.
·
The constant temperature bath of the instrument
adopts high-temperature resistant borosilicate glass, which has good perspective and insulation properties
Technical Specifications:
·
Power supply:
AC(220±10%)V,50Hz;
·
Single Bath tube volume: 1.5L
·
Measurement range: 3~3000mm2/s
·
Sample qty.: (0.3~1)mL
·
Time control accuracy: 0.01℃
·
Timing accuracy: 0.01s
·
Test time: within 3 minutes (the whole process
of measurement, cleaning and drying is within 10 minutes)
·
Temperature control range: room temperature ~ 150℃
·
Repeatability: ≤0.68%
·
Detection unit: Double folded tube viscometer
·
Operation interface: 15 inch IPC
·
Total power consumption: ≤1400W
·
Working temperature: (10~30)℃
Technical Features:
·
Full automatic control, one key start detection,
the test process includes measurement, cleaning, drying, test results calculation and data storage. It will
stop automatically after the test.
·
The measuring speed is fast, the fastest measuring time is no more than 30s,
and the average measuring time is less
than 3 minutes.
·
The instrument has dual solvent automatic cleaning function, which can
quickly clean the folded tube viscometer,
and the consumption of cleaning agent in one cleaning process is not
more than 15ml.
·
The instrument adopts high-precision sensors, and the temperature
of the bathtub is uniform and stable,
with a temperature control accuracy of 0.01 ℃.
·
It is convenient and quick to replace the folded
tube viscometer. The viscometer can be replaced without draining the bath liquid. The replacement can
be completed within 2 minutes.
·
The constant temperature bath of the instrument
adopts high-temperature resistant borosilicate glass, which has good perspective and insulation properties
Technical Specifications:
·
Power supply:
AC(220±10%)V,50Hz;
·
Single Bath tube volume: 1.5L
·
Measurement range: 3~3000mm2/s
·
Sample qty.: (0.3~1)mL
·
Time control accuracy: 0.01℃
·
Timing accuracy: 0.01s
·
Test time: within 3 minutes (the whole process
of measurement, cleaning and drying is within 10 minutes)
·
Temperature control range: room temperature ~ 150℃
·
Repeatability: ≤0.68%
·
Detection unit: Double folded tube viscometer
·
Operation interface: 15 inch IPC
·
Total power consumption: ≤1400W
·
Working temperature: (10~30)℃