Oil Tan Delta Test Set

Categories: Petroleum Testing Equipment

Features: The most advanced heating mode of  high frequency induction is applied to the heating part of this oil tan delta test set, it got the advantage of non-contact of oil cup and heati...


title icon
Product

Description

Features:

The most advanced heating mode of  high frequency induction is applied to the heating part of this oil tan delta test set, it got the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc. Convenience and maneuverability are the most remarkable advantages of this instrument:

1. Digital technology and intelligent automation measurement are applied inside the instrument, multi-mode testing.

2. Big touch screen (320mm×240mm) menu  interface in Chinese is equipped, with which user can be prompted each step during the operating process.

3. The result can be output by printer.

Parameters:

Condition of Use: -5-40 RH<80%

Power Source: AC 220V±10% Without Frequency Limit

AC High Voltage Output: 400V-2200V ±2% Every 100V 50VA

DC High Voltage Output: 00V-2200V ±2%

Temperature Control Induction Stove: Maximal Power 500W

Temperature Control Range: <100

Temperature Measuring Error : ±0.5

Control Temperature Error: 0.1

Control Temperature Time: Room Temperature 90 <20min

Measuring Range: Without Limit

Cx 15PF-300PF

Rx 10M-10T

Resolution tgδ 0.001%

Cx 0.01pF

Rx 0.01

Precision  

delta tgδ:±(Reading*0.5%+0.020%)

delta Cx :±(Reading*0.5%+0.5PF)

delta Rx :±Reading * 10%

Relative Dielectric Loss Constant Εr Calculated Automatically

Volume Resistivity : ρ Calculated Automatically

 


title icon
Product

Reviews

add Review
reviews

    No Review Yet.

quick overview :

Features:

The most advanced heating mode of  high frequency induction is applied to the heating part of this oil tan delta test set, it got the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc. Convenience and maneuverability are the most remarkable advantages of this instrument:

1. Digital technology and intelligent automation measurement are applied inside the instrument, multi-mode testing.

2. Big touch screen (320mm×240mm) menu  interface in Chinese is equipped, with which user can be prompted each step during the operating process.

3. The result can be output by printer.

Parameters:

Condition of Use: -5-40 RH<80%

Power Source: AC 220V±10% Without Frequency Limit

AC High Voltage Output: 400V-2200V ±2% Every 100V 50VA

DC High Voltage Output: 00V-2200V ±2%

Temperature Control Induction Stove: Maximal Power 500W

Temperature Control Range: <100

Temperature Measuring Error : ±0.5

Control Temperature Error: 0.1

Control Temperature Time: Room Temperature 90 <20min

Measuring Range: Without Limit

Cx 15PF-300PF

Rx 10M-10T

Resolution tgδ 0.001%

Cx 0.01pF

Rx 0.01

Precision  

delta tgδ:±(Reading*0.5%+0.020%)

delta Cx :±(Reading*0.5%+0.5PF)

delta Rx :±Reading * 10%

Relative Dielectric Loss Constant Εr Calculated Automatically

Volume Resistivity : ρ Calculated Automatically

 