Application Scenarios The Liquid Particle counter is designed on the principle of light resistance (shading method) and is used to detect the size and number of particles in the liquid. Can be w...
Application Scenarios
The Liquid
Particle counter is designed on the principle of light resistance (shading
method) and is used to detect the size and number of particles in the liquid.
Can be widely used in aerospace, aviation, electric power, petroleum, chemical
industry, traffic, port, metallurgy, machinery, automobile manufacturing and
other fields in the hydraulic oil, lubricating oil, transformer oil, insulating
oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based
hydraulic fluid solid particle pollution tests such as oil, And the detection
of insoluble particles in organic liquid and polymer solution.
Technical Specification:
Light Sources |
Semiconductor laser |
Sensitivity |
0.1 μm |
Sampling volume |
0.2-6000mL |
Sampling accuracy |
Better than ± 1% |
Sampling speed |
5-80mL/min |
Cleaning speed |
5-80mL/min |
Counting error |
<±5% |
Resolution |
<10% |
Repeatability |
RSD < 2% |
Limiting Recombination
Error |
12000-40000
particles/mL |
Working temperature |
-20℃-60℃ |
Online detection
interval time |
Arbitrary setting |
Power supply |
AC100-240V, 50/60Hz |
Battery capacity |
5200mAh |
Battery Run Time |
6-8 hours |
Overall Dimension |
410*320*165mm |
Weight |
8.5kg |
Temperature of test
sample |
0℃-80℃ |
Particle size range |
0.8-600μm (calibrated
to ACFTD calibration 1-100μm or ISO MTD calibration 4-70μm(c)) |
||
Customized detection
channels |
16 channels, any
particle size |
||
Off-line viscosity |
<100cSt (optional
pneumatic chamber for high viscosity) |
||
Pressure range |
Low pressure 0~0.6Mpa,
high pressure up to 42Mpa (optional pressure reducing valve) |
Parameter |
ATP044 |
ATP044/1 |
ATP044/2 |
ATP044/3 |
ATP044/4 |
Dimensions |
310×305×135mm |
410×320×165mm |
275×220×107mm |
365×295×170mm |
420×326×182mm |
Weight |
7.5Kg |
8.5Kg |
2.5Kg |
5.5Kg |
8.5Kg |
Screen |
5.6 inch |
5.6 inch |
3.5 inch |
10.2 inch |
7 inch |
Power source |
Bidirectional piston
pump |
Bidirectional piston
pump |
Metering pump |
Metering Pumps |
Bidirectional piston
pumps |
Battery |
Built-in 5200mAh |
Built-in 5200mAh |
External, optional |
Built-in 8000mAh, no
battery indicator |
Built-in 5200mAh |
Repeatability |
≤2% |
≤2% |
≤5% |
≤5% |
≤2% |
Customized Channels |
16 channels |
16 channels |
No Customization |
No Customization |
64 channels |
System Software |
Multi-level account
password login, editable test results |
Multi-level account
password login, editable test results |
Multi-level account
password login, editable test results |
||
Moisture Viscosity
Temperature Function |
Optional |
Optional |
Moisture temperature
is standard. Viscosity is not optional |
Moisture temperature
is standard. Viscosity is not optional |
Optional |
Computer function |
Connectable to
computer |
Connectable to
computer |
Connectable to
computer |
Application Scenarios
The Liquid
Particle counter is designed on the principle of light resistance (shading
method) and is used to detect the size and number of particles in the liquid.
Can be widely used in aerospace, aviation, electric power, petroleum, chemical
industry, traffic, port, metallurgy, machinery, automobile manufacturing and
other fields in the hydraulic oil, lubricating oil, transformer oil, insulating
oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based
hydraulic fluid solid particle pollution tests such as oil, And the detection
of insoluble particles in organic liquid and polymer solution.
Technical Specification:
Light Sources |
Semiconductor laser |
Sensitivity |
0.1 μm |
Sampling volume |
0.2-6000mL |
Sampling accuracy |
Better than ± 1% |
Sampling speed |
5-80mL/min |
Cleaning speed |
5-80mL/min |
Counting error |
<±5% |
Resolution |
<10% |
Repeatability |
RSD < 2% |
Limiting Recombination
Error |
12000-40000
particles/mL |
Working temperature |
-20℃-60℃ |
Online detection
interval time |
Arbitrary setting |
Power supply |
AC100-240V, 50/60Hz |
Battery capacity |
5200mAh |
Battery Run Time |
6-8 hours |
Overall Dimension |
410*320*165mm |
Weight |
8.5kg |
Temperature of test
sample |
0℃-80℃ |
Particle size range |
0.8-600μm (calibrated
to ACFTD calibration 1-100μm or ISO MTD calibration 4-70μm(c)) |
||
Customized detection
channels |
16 channels, any
particle size |
||
Off-line viscosity |
<100cSt (optional
pneumatic chamber for high viscosity) |
||
Pressure range |
Low pressure 0~0.6Mpa,
high pressure up to 42Mpa (optional pressure reducing valve) |
Parameter |
ATP044 |
ATP044/1 |
ATP044/2 |
ATP044/3 |
ATP044/4 |
Dimensions |
310×305×135mm |
410×320×165mm |
275×220×107mm |
365×295×170mm |
420×326×182mm |
Weight |
7.5Kg |
8.5Kg |
2.5Kg |
5.5Kg |
8.5Kg |
Screen |
5.6 inch |
5.6 inch |
3.5 inch |
10.2 inch |
7 inch |
Power source |
Bidirectional piston
pump |
Bidirectional piston
pump |
Metering pump |
Metering Pumps |
Bidirectional piston
pumps |
Battery |
Built-in 5200mAh |
Built-in 5200mAh |
External, optional |
Built-in 8000mAh, no
battery indicator |
Built-in 5200mAh |
Repeatability |
≤2% |
≤2% |
≤5% |
≤5% |
≤2% |
Customized Channels |
16 channels |
16 channels |
No Customization |
No Customization |
64 channels |
System Software |
Multi-level account
password login, editable test results |
Multi-level account
password login, editable test results |
Multi-level account
password login, editable test results |
||
Moisture Viscosity
Temperature Function |
Optional |
Optional |
Moisture temperature
is standard. Viscosity is not optional |
Moisture temperature
is standard. Viscosity is not optional |
Optional |
Computer function |
Connectable to
computer |
Connectable to
computer |
Connectable to
computer |
No Review Yet.
Copyrights © 2025 All Rights Reserved by Atico
Product
Reviews
add Review
reviews
No Review Yet.