This test method is used for the determination of the distillation characteristics of petroleum products, biodiesel, and fractions that may decompose if distilled at atmospheric pressure. This test...
This test
method is used for the determination of the distillation characteristics of
petroleum products, biodiesel, and fractions that may decompose if distilled at
atmospheric pressure. This test method covers the determination, at reduced
pressures, of the range of boiling points for petroleum products and biodiesel
that can be partially or completely vaporized at a maximum liquid temperature
of 400 °C. Both a manual method and an automatic method are specified.
The boiling
range is directly related to viscosity, vapor pressure, heating value, average
molecular weight, and many other chemical, physical, and mechanical properties.
Any of these properties can be the determining factor in the suitability of the
product in its intended application.
Main technical specification
and parameters:
·
Power supply: AC(220±10%), V 50Hz
·
Total power consumption: ≤1800W
·
Flask heating furnace power:(0~500)W
(continuously adjustable)
·
Range of the temperature control for condensate
circulating water: room temperature +5℃(lowest 30℃)~80℃±3℃,continuously adjustable
·
Cold trap working mode and temperature:
semiconductor refrigeration,lowest temperature: ≤-40℃
·
Absolute pressure setting: 2mmHg、5mmHg、10mmHg、20mmHg、50mmHg
·
Absolute pressure measurement range: (2.00~170.00)
mmHg, automatic constant
·
Accuracy of absolute pressure control: Pressure<1kPa(7.5mmHg)
accuracy<0.01kPa(0.075mmHg) pressure≥1kPa(7.5mmHg),accuracy≤1% of absolute
pressure
·
Working environment: Ambient temp.:5~35℃, RH:<
85%
·
Dimension: 800mm×500mm×900mm(L×W×H)
·
Net weight: 61kg
Main structure and functions:
·
Vacuum pump: built-in vacuum pump
·
Cooling fan: located next to the heating
furnace, automatically opens to cool the
heating furnace after test
·
Oil temperature sensor: used for measuring the
temperature of oil sample in the distillation flask
·
⑷Distillation column assembly: vacuum jacket distillation
column assembly for experimental distillation
·
Oil vapor temperature sensor: plug the sealant
into the top of the distillation flask to detect the temperature of the oil
vapor
·
Cold trap:
built-in, semiconductor-cooled hydrazine
·
Collection bottle of the cold hydrazine residue:
used to collect the residual liquid of cold hydrazine, the liquid can be taken
out and weighed for further analysis
·
LCD touch screen: 10.1 inch LCD color touch
screen, man-machine interface
·
Power switch: the main power switch, long press
5 seconds, the instrument will connect to the working power
·
Sketch map: each interface function is shown on
the right panel
·
Distillation flask: 500ml heat resistant
distillation flask, put sample inside and put it on the heating furnace
·
Heating furnace: electric heating furnace, used
for heating sample, the heating power can be adjusted on the screen with an
accuracy of 0.5%
·
Heating furnace lifting platform: up, down or
stop is controlled by the button on the screen, with the limit protection
·
Receptor lamp: installed under the receptor,
easy to read the distillation volume
·
Receptor: 200ml receptor, the drop chain is
hanged inside to receive the distillate
·
Clamp of the receptor: used to clip the receptor
This test
method is used for the determination of the distillation characteristics of
petroleum products, biodiesel, and fractions that may decompose if distilled at
atmospheric pressure. This test method covers the determination, at reduced
pressures, of the range of boiling points for petroleum products and biodiesel
that can be partially or completely vaporized at a maximum liquid temperature
of 400 °C. Both a manual method and an automatic method are specified.
The boiling
range is directly related to viscosity, vapor pressure, heating value, average
molecular weight, and many other chemical, physical, and mechanical properties.
Any of these properties can be the determining factor in the suitability of the
product in its intended application.
Main technical specification
and parameters:
·
Power supply: AC(220±10%), V 50Hz
·
Total power consumption: ≤1800W
·
Flask heating furnace power:(0~500)W
(continuously adjustable)
·
Range of the temperature control for condensate
circulating water: room temperature +5℃(lowest 30℃)~80℃±3℃,continuously adjustable
·
Cold trap working mode and temperature:
semiconductor refrigeration,lowest temperature: ≤-40℃
·
Absolute pressure setting: 2mmHg、5mmHg、10mmHg、20mmHg、50mmHg
·
Absolute pressure measurement range: (2.00~170.00)
mmHg, automatic constant
·
Accuracy of absolute pressure control: Pressure<1kPa(7.5mmHg)
accuracy<0.01kPa(0.075mmHg) pressure≥1kPa(7.5mmHg),accuracy≤1% of absolute
pressure
·
Working environment: Ambient temp.:5~35℃, RH:<
85%
·
Dimension: 800mm×500mm×900mm(L×W×H)
·
Net weight: 61kg
Main structure and functions:
·
Vacuum pump: built-in vacuum pump
·
Cooling fan: located next to the heating
furnace, automatically opens to cool the
heating furnace after test
·
Oil temperature sensor: used for measuring the
temperature of oil sample in the distillation flask
·
⑷Distillation column assembly: vacuum jacket distillation
column assembly for experimental distillation
·
Oil vapor temperature sensor: plug the sealant
into the top of the distillation flask to detect the temperature of the oil
vapor
·
Cold trap:
built-in, semiconductor-cooled hydrazine
·
Collection bottle of the cold hydrazine residue:
used to collect the residual liquid of cold hydrazine, the liquid can be taken
out and weighed for further analysis
·
LCD touch screen: 10.1 inch LCD color touch
screen, man-machine interface
·
Power switch: the main power switch, long press
5 seconds, the instrument will connect to the working power
·
Sketch map: each interface function is shown on
the right panel
·
Distillation flask: 500ml heat resistant
distillation flask, put sample inside and put it on the heating furnace
·
Heating furnace: electric heating furnace, used
for heating sample, the heating power can be adjusted on the screen with an
accuracy of 0.5%
·
Heating furnace lifting platform: up, down or
stop is controlled by the button on the screen, with the limit protection
·
Receptor lamp: installed under the receptor,
easy to read the distillation volume
·
Receptor: 200ml receptor, the drop chain is
hanged inside to receive the distillate
·
Clamp of the receptor: used to clip the receptor